How much attic ventilation do I need?

Enter your attic floor area and pick the 1:150 or 1:300 standard — get the net free area (NFA) required, the soffit vent count and the ridge vent length, instantly.

Attic details
Ventilation type
Required net free area
0.747

= 7467 cm²

Soffit vents needed
19
std 406 × 203 mm vents
Ridge vent length
19.6 m
at std ~381 cm²/m NFA

NFA = floor area ÷ 150. Vent counts use 50% NFA screen factor for a standard 406 × 203 mm soffit vent and 18 in²/ft (~381 cm²/m) for ridge vent — typical industry values; actual product NFA varies. Verify with your local authority before specifying.

Common questions

How do you calculate attic ventilation?
Divide the attic floor area by 150 to get the minimum net free area (NFA) of ventilation required. For example, a 1,200 sq ft attic needs 1,200 ÷ 150 = 8 sq ft of NFA. If at least 40% of that NFA is placed near the ridge and a vapour barrier is present in the attic floor, the guideline allows a 1:300 ratio (half as much), so the same attic would need 1,200 ÷ 300 = 4 sq ft of NFA.
What is the 1 in 150 rule for attic ventilation?
The 1:150 rule says the total net free area of attic vents should be at least 1 sq ft for every 150 sq ft of attic floor area. It is the widely-used standard guideline for attics where the ventilation openings are not balanced between low (soffit) and high (ridge) positions. Most residential attic ventilation designs use this ratio as a starting point.
What is the 1:300 ventilation rule?
The 1:300 rule allows half the ventilation area of the 1:150 rule, but only when at least 40% — and not more than 50% — of the total net free area is located in the upper half of the roof space (near the ridge), and a vapour barrier is installed across the attic floor. This balanced arrangement creates a more effective air path from soffit to ridge, allowing the reduced total area to work as well as the larger 1:150 area.
How many soffit vents do I need for my attic?
A standard 16 × 8 in screened soffit vent has about 64 sq in (0.44 sq ft) of net free area at a 50% NFA screen factor. The calculator uses the exact figure (64 sq in = 0.4444 sq ft per vent) and shows the number of soffit vents that would cover the full required NFA on their own. In a balanced soffit-to-ridge design, install roughly half that count at the eaves and match it with the ridge vent length shown. Continuous soffit strips have a different NFA per linear foot — check the manufacturer's label.